Each platform unit shall be installed so that
WebFeb 23, 2024 · Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and … Webbuilding. As each level of brick or concrete block is put in place, the scaffold is cranked up to the next level. When the work is done at the top of the wall, then the scaffold is cranked back down to the ground and disassembled. Gilbane witnesses testified this scaffold had been on the job site for months. TE 114.
Each platform unit shall be installed so that
Did you know?
WebEach platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is … Web(1) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space …
Webrollers if the suspended platform is not more than 130 feet (or 39.6 meters) above a safe working surface; and An alternative stabilization system if a registered professional … Web3314.5.1 Platform Spacing. Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (25 mm) wide except where a qualified person can demonstrate that a wider space is ...
WebAug 12, 2024 · Each platform unit shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than _____ inch … Web(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space …
Web210.52 (C) (1) Electrical Receptacles Along Wall Counter Spaces. A receptacle outlet shall be installed at each wall counter space that is 12 inches (300 mm) or wider. Receptacle outlets shall be installed so that …
Web3314.5.1 Platform Spacing. Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between … side effects of bluechewWeb1926.451(b)(1)(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the … side effects of blue lotusWebEach platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the … side effects of blueberries for menWeb(1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (i) Each platform unit shall be installed so that the space between … the pin-up plot movieWebAn application can be called a platform if it is a host to other programs. For example, Web browsers accept third-party plug-ins, and the browser becomes a platform to interface … side effects of blueberry extractWeb505.3 Equipment Platforms. Equipment platforms in buildings shall not be considered as a portion of the floor below. Such equipment platforms shall not contribute to either the … the pin upsWebpermanent sign shall be installed on the switch enclosure or immediately adjacent to open ... (6 ft 7 in.) above the floor or working platform. Exception No. 1: On busway installations, fused switches and circuit breakers shall be permitted to be located at the same level as the busway. ... shall be installed so as to completely cover the ... side effects of body wraps