Ion-tof pdf
Web27 feb. 2015 · The anthocyanin extract from a domestic Perilla cultivar (Perilla frutescens var. acuta) were isolated and characterized with high mass accuracy and multi-dimensional fragmentation by means of ultra-performance liquid chromatography (UPLC) and electrospray ionization-ion trap-time of flight mass spectrometry analysis (ESI-IT-TOF … WebAgilent 7250 GC/Q-TOF Data Sheet Parameter Specification Ionization mode (standard) Conventional electron ionization (EI) at 70 eV Ionization mode (standard) Low energy EI Electron energy Settable, 5-200 eV Ion source material Noncoated, proprietary inert source Ion source temperature Settable, 100 to 350 °C
Ion-tof pdf
Did you know?
Time-of-flight mass spectrometry (TOFMS) is a method of mass spectrometry in which an ion's mass-to-charge ratio is determined by a time of flight measurement. Ions are accelerated by an electric field of known strength. This acceleration results in an ion having the same kinetic energy as any other ion that has the same charge. The velocity of the ion depends on the mass-to-charge ratio (hea… Webmass of the precursor ion; the elevated energy leads to the generation of spe-cific accurate mass fragment ions for additional confirmatory purposes. UNIFI® data processing: Samples were processed automatically using the standard method which incor-porates both targeted (I) and semi-targeted analysis (II). In addition, the Dis-
WebFerramentas. Espectrômetro de massa. A espectrometria de massas é uma técnica analítica física para detectar e identificar moléculas de interesse por meio da medição da sua massa e da caracterização de sua estrutura química. O princípio físico básico de um espectrômetro de massa consiste em criar íons de compostos orgânicos por ... Web基质辅助激光解吸/电离. 基质辅助雷射脫附电离 (英語: Matrix-assisted laser desorption/ionization ,MALDI)是一种用于 质谱法 的溫和 离子化 技术,可以得到用常规离子化方法容易解离為碎片的一些完整大分子质谱訊息,比如 生物分子 类的 DNA , 生物高分 …
Web14 sep. 2024 · In the positive-ion mode, groups containing C20-OH substituents easily lose a molecule of H 2 O (m/z 18.0106 Da). In the No-C20-OH substituent group, strong [M + H] + ions are observed [ 15 ]. Moreover, if the compound has a glycosyl group in its structure, a fragment ion that loses glycosyl (C 6 H 10 O 5 , m/z 162.0528) will be generated. WebToF-SIMS法では,一次ビームまたは分析ビームと呼ばれるイオンのエネルギービーム(例えば,我々のToF-SIMS V装置(Ion-ToF GmbH,ドイツ)ではBi+,30 keV)を試料表面に向ける。この一次イオンビームからエネルギーおよび運動量が試料表面に移動
Web1 aug. 2001 · peaks was approaching one ion TOF pulse per TDC dead- time (20 ns) for a single anode, and the isotopic pattern shows definite signs of saturation, similar to those …
small tire manufacturersWebNatural food preservatives are being sought extensively as a safe alternative to chemical food preservatives. This study aimed to identify potential natural preservatives from herbs using single-photon ionization time-of-flight mass spectrometry (SPI-TOF-MS). Five Artemisia species and four other herbs were analyzed, and the random forest (RF) … small tire machineWebETP's next generation Fast-TOF incorporating eXtion® offers more life, linearity, sensitivity, robustness and RoHS compliance. The NEW Fast-TOF Plus provides paramount … highway use feeWebA procedure for quantitative time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of the re-oxidation thermallyreduced of iron oxide particles in a ceramic matrix is … highway use fee ct.govWebQ-TOF analog-to-digital (ADC) detection systems provide accurate stable isotope ratios. ADC detection records multiple ion events, allowing accurate mass assignments over a … small tire patchesWebsecond ion guide is driven by an RF power ampli-fier operated at 5 MHz. The high 5 MHz frequency is key to achieving maximum ion transmission over a wide (> m/z100– 3000) … highway use fee appliedWebThe TOF-SIMS investigations were performed using an ION-TOF instrument (TOF-SIMS IV) equipped with a 25 kV pulsed 69Ga+ primary ion gun in the static mode. To obtain the … small tire pneumatic bead expander