Photometric test report
WebPhotometric Test Report UL1598-2008 ANSI C82.77-2002 IES LM-79-2008 Relevant Standards Mentor, OH 44060 9150 Hendricks Road Christine Beltzer Eye Lighting … WebThe observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. ... Photometric and Electrical Measurements – Distribut ion Method Power Factor 79.32 Criteria Result WT210 146919 ...
Photometric test report
Did you know?
WebThe Viso software also creates IES (Illuminating Engineering Society) files for each test report. IES is an industry standard file format created for the easy electronic transfer of photometric test data, which is widely used by lighting manufacturers for … WebPhotometric Testing. Ensuring safety, quality and performance from the simplest light source to high-tech lighting systems ... CMVSS108 (Canada) and SAE standards for …
WebMeasure distribution photometry and input electrical parameters and report candela distribution, calculated lumen output, voltage (V), current (A) and power (W). Sphere … WebEVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 13 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM NAME: LED ceiling light SPEC.:N/A MFR.: TYPE:N/A DIM.: N/A SUR.:N/A WEIGHT:N/A SERIAL No.:N/A Shielding Angle:N/A Test:U:120.0V I:0.1251A P:13.88W PF:0.9244 Lamp Flux:988.995x1 lm cc w fc RCR RCR:Room Cavity Ratio …
WebPhotometric Test Report Relevant Standards RANSI C82.77:2014 RIES LM-79-2008 Data Number Test Date Issue Date 2024/12/26 2024/12/26 The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Deliver Co.,Ltd. WebIt is important that separate electrical measurements are taken for each type of photometric test included in the LM-79 report (i.e., integrating sphere and distribution methods discussed below), so that luminaire eicacy is calculated using light output and power measurements from the same test. Light Output (Luminous Flux) Essential Data
WebPhotometry testing: This is a approved method which describes the procedure to be followed and precautions to be observed in performing reproducible measurements of …
WebThis report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Kyle Spaziani, Project Handler Photometric Test Report UL1598-2008 ANSI C82.77-2002 IES LM-79-2008 Relevant Standards United States Mentor, OH 44060 9150 Hendricks Road Christine Beltzer irvin marriott lawsuitWebLM-79 reports from Caliper approved testing lab. 2. Carefully review the reports - even the picture. 3. Use credible manufacturers with track records, but don’t discourage start-ups. … irvin mayfield newsWebLM-79 test method uses absolute photometry to directly measure total lumen output for a particular configuration of an integrated LED lamp or luminaire with LED light sources operated in situ; consequently, the efficiency of an integrated LED luminaire cannot be calculated in a standard manner. irvin mayfield albumsWebUsed by lighting designers to model the illumination performance of a lighting scheme using commercial lighting design programs. An IES file is commonly referred to as "photometric data" for a luminaire. Customers are issued a complete test report (in PDF format) along with the resulting IES file for use in most application and modeling programs. portalrrhh bureauveritas clWebof photometric test included in the LM-79 report (i.e., integrating sphere and distribution methods discussed below), so that luminaire eicacy is calculated using light output and … irvin mayfield royal sonestaWebPHOTOMETRIC DATA SHEET PHOTOMETRIC TEST REPORT NAME: Round Integrated LED Bollard with Louvers PART NUMBER: BLRK-FL1-xK25BR740 MFR.: Super Bright LEDs TYPE: DIM.: SUR.: WEIGHT: SERIAL No.: Shielding Angle: 0 30 60 90 120 150-/+180-150-120-90-60-30 UNIT:cd AVERAGE BEAM ANGLE(50%):340.7 DEG 0 40 80 120 160 200 INTENSITY … portalroboter achsenWebLight Laboratory provides Photometric and Color testing done for SSL/LED Lighting Products using procedures outlined in IES LM-79-08. Complete test report including lumens, light distribution, efficacy, CCT, CRI, V-A-W, PF and THD. portals and shite bl3