Readily accessible electrical definition
WebThe definition of readily accessible does not preclude the use of a locked door for service equipment or rooms containing service equipment, provided those for whom ready access is necessary have a key (or lock combination) available. Sections 230.70(A)(1) and 230.205(A) require service-disconnecting means to be readily accessible. WebApr 5, 2004 · In accordance with 29 CFR 1910.399, readily accessible is defined as "capable of being reached quickly for operation, renewal, or inspections, without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders, chairs, etc."
Readily accessible electrical definition
Did you know?
WebMar 23, 2024 · (a) Readily Accessible – Capable of being reached quickly for operation, renewal, or inspections without the requirement of climbing over or removing obstacles or … Web(a) A device which is not designed, redesigned, used, or intended for use as a weapon; (b) Any device, although originally designed as a weapon, which is redesigned so that it may be used solely as a signaling, line-throwing, safety, or similar device; (c) Any shotgun other than a short-barreled shotgun; or
WebAn additional 2 percent of the total units (or at least one unit, whichever is greater) must be made accessible for persons with hearing or vision impairments. In circumstances where … WebAug 2, 2024 · A notation was added to this definition to allow a key to be used to gain access to electrical equipment. ... or some other type of electrical equipment or enclosure is ok. I’ve seen generators like the one pictured below with a disconnect next to it because the breaker inside was not readily accessible. Accessible, Readily (Readily Accessible).
WebOct 24, 2005 · Response: In accordance with 29 CFR 1910.399, Readily accessible is defined as "capable of being reached quickly for operation, renewal, or inspections, without … WebAug 31, 2024 · The disconnect for shore power receptacles must be readily accessible and not more than 30 in. from the receptacle it controls. Circuit breakers or switches in marina power outlets can be used for the shore power receptacle disconnect [Sec. 555.36 (B)]. Equipment grounding conductor
WebMay 7, 2008 · Response: In accordance with 29 CFR 1910.399, Readily accessible is defined as "capable of being reached quickly for operation, renewal, or inspections, without … orbital velocity of moon 5 digitsWebMay 15, 2016 · Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is … orbital velocity of earth in miles per hourWebAug 1, 2007 · Constitutes the main control and cutoff of the electricity supply. Usually consists of circuit breakers (or switches and fuses) and their accessories. Connects to the load end of service conductors in a … ipostal websiteWebThe 2014 edition defined readily accessible as capable of being reached quickly for operation, renewal or inspections without requiring those to whom ready access is requisite to actions such as to use tools, to climb over or remove obstacles, or to resort to portable ladders, and so forth. ipostsignalsWebAug 2, 2024 · Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is … orbital velocity of satellite class 11WebApr 12, 2024 · accessible. (æksesɪbəl ) adjective. If a place or building is accessible to people, it is easy for them to reach it or get into it. If an object is accessible, it is easy to … ipostal1 virtual business addressWebJan 10, 2024 · Article 100 Definition: (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is requisite to actions such as to use tools, climb over or remove obstacles, or to resort to portable ladders, and so forth. ipostparcels uk login